Flow Summary Report

Report Description

The Flow Summary report lists the instantaneous flow rate through a single regulator or a group of regulators at specified intervals during a reporting period.

To report the average flow rates, rather than the instantaneous flow rate, use the Average Flow Report.

Note

To report on groups of regulators you must first set up Summary Regulator Groups. See Summary Regulator Groups Module for more details.

Report Parameters and Options

Parameter Description

Regulator/Regulator Group

Select an individual regulator or a group of regulators for the report. If you choose to report on a group, you can select from any of the configured Summary Regulator Groups.

Date Lodged From/To

Specify the reporting period

Start Time

The Flow Summary report lists the flow at fixed points during the day. The time of the first reported flow data point each day is given by this parameter and the interval between flow data points is given by the Change Interval.

Change Interval

This specifies in hours how frequently the flow is reported each day.

For example, if the start time is 00:00 and the change interval is 12 hours, the flow is reported at 00:00 and 12:00 each day.

Report Output

Property Description

Regulator

Name and description of the regulator and of the channel

Time/Date

Time and date of each data point

Flow

Instantaneous flow at each data point.

Related Reports

Average Flow Report

The Average Flow report lists the average flow rate through a single regulator or a group of regulators at specified times of day during the reporting period.