Meter Reading Report
Report Description
The Meter Reading report generates a list of outlets for the use of field officers who can take a copy of the output into the field, complete the meter readings and return the report for manual or automatic input.
Report Parameters and Options
Parameter | Description |
---|---|
Area |
Select an area for which to run the report. |
None/Group/Section |
Refine the area selection by specifying a particular group or section, or choose none to generate the report for the whole area. |
Start regulator |
Regulator or regulators to use for generating the report. The report lists outlets in downstream order from the specified regulators.
Whether or not you need to specify the start regulator depends on how you have defined the report area. |
Meter type |
Filter the list of meters displayed (these options may vary depending on your system configuration):
|
Exclude PPMs |
Exclude pipe permitted meters from the report. |
Report on |
A set of options to restrict the outlets that are printed in the report:
|
Line spacing |
Line spacing between each row of the report. |
Include remote meter readings |
Include meter readings that were read remotely from a SCADA system. |
Format for meter reading import process |
Format the report so that the completed readings file can be automatically imported in the Meter Reading Entry Module. See Importing Meter Readings for more details. This option is only available for reports in CSV (comma separated values) format. If the option is disabled, check that the Generate As option is set to CSV. |
Report Output
Property | Description |
---|---|
Outlet |
Outlet name |
Type |
Outlet type - for example, slipmeter, blademeter. |
Property |
Property for which the meter reading applies |
Owner |
Party who is the property owner |
Previous value |
Last meter reading value |
Meter reading time/date |
Last meter reading time and date |
Estimated usage |
Estimated usage since the last reading |
Expected reading |
Expected meter reading calculated from the last reading and the estimated usage |
Entitlement remaining |
Entitlement remaining for the property. |
Reading |
Blank field for entering the meter reading |
Time |
Blank field for entering the meter reading time |
Date |
Blank field for entering the meter reading date |
Related Reports
Meter Reading Variations Report
The Meter Reading Variations report generates a list of meter readings for an outlet and property where the actual reading differed from the estimated reading.
The Meter Reading Status report provides the number of:
- Outlets in the report area
- Outlets with good meter readings (that is, readings that match the estimated usage)
- Outlets without meter readings
- Outlets with a reason provided for the reading. These are readings where a variation was accepted, or an adjustment was made for which a reason was entered.
The report also lists the details of all missing readings, or those with variations or adjustments.
The Meter Usage report records the reading and usage for meters in the selected area as at the beginning and the end of the report period.
The Outlet Location report lists the location of all outlets in the report area using the Australian Map Grid (AMG) coordinate system.